LFADJ Details How Its Diesel Light Tower Range Differs by Mast Type


LFADJ, the lighting brand of Zhejiang Longfa Lighting Co., Ltd., is setting out how the three towers in its diesel light tower range differ, and why the mast type matters more to a jobsite than the lamp count printed on a brochure.


YUEQING, China, October 31, 2026
— LFADJ, the lighting brand of Zhejiang Longfa Lighting Co., Ltd., is setting out how the three towers in its diesel light tower range differ, and why the mast type matters more to a jobsite than the lamp count printed on a brochure. All three models, the D951, D955 and D957, carry the same four-lamp head and the same diesel generator. What separates them is how the mast goes up, how often a crew can afford to raise it, and whether the transport envelope fits the route into the work zone.

This release describes product pages the company already publishes. No new model, plant expansion, partnership or test result is announced. Its purpose is narrower: to show contractors, rental fleets and plant engineers which decisions about mast type, lamp load and transport envelope should be settled before quotations are compared side by side.

What a diesel light tower has to do on a night shift

A towable light tower is a trailer that carries a telescopic mast, a lamp head and its own generator, so a work area can be lit where no fixed supply exists. In LFADJ’s published specifications, that package is four 400 W LED lamps fed by a diesel generator, with 340° rotation at the mast so the beam can be turned toward the task without moving the trailer.

Since the lamp head is common to all three models, a buyer comparing them is not really comparing light output. What buyers are really comparing is the lifting mechanism, the effort it asks of the operator, and the service work each mechanism adds. That is why the company sorts its towers by mast rather than by wattage.

Where it stops: lamp wattage is not illuminance. Four 400 W heads describe how much power goes in, not how much light lands on the work plane; beam distribution, aiming and nearby structures decide the rest.

Manual winch lifting on the D951

The D951 combines a 7.5 m manual winch mast with 340° rotation. Lifting is done by hand: the operator winds the mast up, locks it, and lowers it the same way when the shift ends.

That arrangement suits sites where the tower goes up once and stays put for the night. A road crew setting up at dusk and packing down at dawn has little use for powered lifting, and a hand winch takes a drive system off the maintenance list. LFADJ’s mast and power matrix names the winch, cable, guides and locks as the service focus, and asks one plain question first: can the operator handle the lifting and locking procedure?

Where it stops: frequent repositioning. Once a crew has to lower and raise the mast several times a shift to follow a moving task, manual effort becomes the bottleneck, and that is the point at which LFADJ steers buyers toward a powered mast.

Hydraulic lifting on the D955, in two heights

The D955 uses a hydraulic mast with 340° rotation and is the one model in the range offered at two heights. Its product page lists a 9 m package carrying four 400 W LED lamps, for 1.6 kW of combined rated lamp input, plus a 7 m mast configuration that can be discussed against the site brief.

Hydraulic lifting earns its place when deployment is repeated night after night and the lifting arrangement shapes the site workflow. It also brings fluid, hoses and seals into the service plan, so the company asks buyers to leave service access for the hydraulic system in the site layout.

Height changes shipping as well. Both versions keep a 1650 × 1450 mm footprint in the specification table, yet the transport height is 2350 mm for the 7 m variant and 2650 mm for the 9 m variant. A depot door that clears one may not clear the other.

Where it stops: a taller mast is not automatically more useful light. LFADJ’s own page describes the two heights as two deployment envelopes rather than a fixed coverage ratio, and leaves optics, aiming and the target work plane to decide what the crew actually sees.

Pneumatic lifting on the D957

The D957 reaches 7.5 m on a pneumatic telescopic mast, again with 340° rotation. Here the lifting force comes from an air system, so the buying questions shift to the air supply, the control arrangement and the operating environment.

Handover matters more with this mechanism. Lowering instructions and air-system maintenance instructions should travel with the equipment, and the upkeep list moves to air connections, controls and mast seals.

Where it stops: the air system does not run the lamps. Mast actuation and lamp supply are separate questions, and a quotation that answers only one of them leaves the other open.

Lamp load against generator output

All three towers list 120 V, 60 Hz and 2.4 kW generator output, with four 400 W LED lamps and a 100 L fuel tank. Four lamps at 400 W each add up to 1.6 kW, which leaves headroom on paper.

Published item

D951

D955

D957

Mast lifting

Manual winch

Hydraulic

Pneumatic

Mast height

7.5 m

9 m package; 7 m version

7.5 m

Lamps

4 × 400 W LED

4 × 400 W LED

4 × 400 W LED

Generator output

2.4 kW, 120 V / 60 Hz

2.4 kW, 120 V / 60 Hz

2.4 kW, 120 V / 60 Hz

Fuel tank

100 L

100 L

100 L

Dry / wet weight

1050 / 1150 kg

1050 / 1150 kg

1050 / 1150 kg

A generator rating means little until the lighting load and everything else on the circuit are listed together. Power tools, chargers and their starting loads all draw on the same output, so the company asks for running and starting requirements of connected equipment, matched to the outlets and protective devices at the destination.

Where it stops: a bigger tank does not stretch a shift on its own. LFADJ makes this point directly on its tower page: when the operating load or the refuelling plan changes, tank size stops predicting how long the lights stay on.

Transport envelope and weight for a towable unit

D951 and D957 have a listed transport envelope of 1650 × 1450 × 2350 mm. According to its product page, the D955 weighs 1,050 kg dry and 1,150 kg wet, and packing, accessories and restraints need their own shipping-weight entry on top of that.

For export orders the loading plan is just as concrete: four D955 units in a 20 ft container and eight in a 40 ft container. Mast version, packing method and accessories have to be coordinated with that plan before freight is booked, because the taller variant changes the height that goes into the box.

On site, the stored footprint is only half of the check. For the 7 m D955, the company’s homepage gives a deployed footprint of 2,650 × 2,450 mm, roughly 6.49 m² against about 2.39 m² in transport form. Stabilizers, ground support and service access all sit inside that larger rectangle.

Where it stops: a mobile light tower that fits the truck may still not fit the gate, the overhead line clearance or the soft verge where it has to stand.

Light levels, exhaust and the limits of a diesel light tower

For U.S. construction, OSHA 29 CFR 1926.56 Table D-3 sets 5 foot-candles for general construction area lighting, 3 foot-candles for areas such as excavation, access ways and refueling, and 10 foot-candles for construction plant and shops. Those minimums attach to the activity, which is why a useful brief names the task and the measurement plane instead of a wattage target.

Diesel equipment also carries a placement rule that has nothing to do with light. According to the CDC, carbon monoxide from small engines and generators can build up and poison people, and portable generators should run outdoors more than 20 feet from windows, doors and vents. LFADJ’s tower pages apply the same logic to light towers: keep combustion equipment outdoors, with exhaust pointed away from air openings.

Limit: hazardous atmospheres. A standard industrial light tower is not interchangeable with an explosion-proof model approved for a specific gas or dust hazard, and the company handles that as a separate product route rather than a tower option.

What to settle before comparing quotations

A site-to-quote worksheet published by the company keeps engineering and purchasing working from the same inputs. A comparable request covers:

  • Mast type and height variant, with the deployment frequency that justifies it.
  • Lamp quantity, the available electrical supply and every other connected load.
  • Transport dimensions, access openings, packing and the delivery destination.
  • Required documents, including model-specific operation and wiring manuals.
  • Whether the deadline means factory dispatch or arrival on site.

Delivery for the listed tower models is 45–60 days, so a required arrival date shapes the configuration discussion from the start. The company’s engineering team sums up the selection order in one line: “Review the deployment space, the power supply and the lighting task together before choosing the mast.”

About Zhejiang Longfa Lighting Co., Ltd.

Zhejiang Longfa Lighting Co., Ltd. was founded in 2013 in Yueqing, Zhejiang, China, and sells under the LFADJ brand. The company works across R&D, manufacturing, trade and service for industrial, mobile, explosion-proof and emergency lighting, and its production equipment includes cutting, bending and welding equipment. Its range covers mobile light towers, telescopic lighting towers, mobile lighting systems, portable work lights, explosion-proof lighting and industrial emergency lighting systems.

Contractors and rental fleets comparing tower configurations can review LFADJ’s industrial mobile lighting range. Enquiries can be sent to info@lfadjlight.com, the address listed on the company’s contact page.

Company Information

Zhejiang Longfa Lighting Co., Ltd.

info@lfadjlight.com

https://lfadjlight.com/

SOURCE: Zhejiang Longfa Lighting Co., Ltd.